Issue |
J Extra Corpor Technol
Volume 22, Number 2, June 1990
|
|
---|---|---|
Page(s) | 85 - 90 | |
DOI | https://doi.org/10.1051/ject/1990222085 | |
Published online | 21 August 2023 |
Editorial/review
A Comparative Evaluation of Pulmonary Artery Balloon Counterpulsation and a Centrifugal Flow Pump in an Experimental Model of Right Ventricular Infarction
Division of Surgery, Walter Reed Army Institute of Research (MGM, BW, GMG), Departments of Medicine (AJT) and Cardiovascular Surgery (FHE), Walter Reed Army Medical Center, Washington DC, and the Uniformed Services University of the Health Sciences (GMG), Bethesda, MD
* Address correspondence to: Allen J. Taylor MD, Department of Medicine, Walter Reed Army Medical Center, Washington DC, 20307-5001.
To compare the efficiency of pulmonary artery balloon counterpulsation and a centrifugal flow pump in reversing the hemodynamic consequences of acute right-sided heart failure, we employed both devices in 14 Yorkshire pigs in which right ventricular infarction was created via surgical ligation of branches of the right coronary artery. Pulmonary artery balloon counterpulsation improved some of the indicators of right heart failure, as manifested by significantly decreased right atrial pressure and increased mean systemic blood pressure. In contrast, the centrifugal flow pump consistently and significantly reversed all of the hemodynamic consequences of right ventricular infarction. In comparison to pulmonary artery balloon counterpulsation, the centrifugal flow pump resulted in lower right atrial pressures (p=0.020), lower mean pulmonary pressures (p<0.0001), increased left atrial pressures (p=0.026), increased cardiac output (p<0.0001), and increased mean systemic blood pressures (p<0.0001). Possible mechanisms to explain the superiority of the centrifugal flow pump include better hemodynamic unloading of the failing myocardium and independence from right ventricular output.
Key words: Right ventricular failure / circulatory assistance / pulmonary artery balloon counterpulsation / centrifugal flow pump / swine
© 1990 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.