Open Access

Table 1

Direct B/Ex-THV implantation into the mechanical prosthesis frame (valve-in-frame) + HeartMate 3 LVAD implantation: 9 cases. The technical specifications.

Pt No Previous surgery (Mechanical Valve Replacement)
Internal diameter, mm
MyVal sizes (mm) AV/MV positions
CPB Time (min) Cross Clamp Time (min) Combined surgery
AV MV AV MV AV MV
1 St. Jude Masters 27 25.5 27.5 194 43 LVAD HM3
2 MEDINZH-2 27 22.1 26 210 84 LVAD HM3
3 Carbomedics Standard 29 24.2 24.5 127 41 LVAD HM3
4 St. Jude Masters 19 St. Jude Masters 31 17.8 27.2 21.5 27.5 185 86 LVAD HM3
5 St. Jude Masters 31 27.2 27.5 162 28 LVAD HM3
6 St. Jude Masters 31 27.2 27.5 107 21 LVAD HM3
7 St. Jude Masters 21 St. Jude Masters 31 19.6 27.2 20 27.5 209 51 LVAD HM3
8 MIKS 23 MIKS 29 21.0 26.6 27.5 30 146 60 LVAD HM3
9 MEDINZH-2 29 24.1 29 202 29 LVAD HM3