Articles citing this article

The Citing articles tool gives a list of articles citing the current article.
The citing articles come from EDP Sciences database, as well as other publishers participating in CrossRef Cited-by Linking Program. You can set up your personal account to receive an email alert each time this article is cited by a new article (see the menu on the right-hand side of the abstract page).

Cited article:

Does the venous cannulation method affect gaseous embolic load to the patient during extracorporeal circulation?

Petronella Torild, Anna Corderfeldt Keiller and Tor Damén
Perfusion (2025)
https://doi.org/10.1177/02676591251344859

Dynamics of appearance and decay of gaseous microemboli during in vitro extracorporeal circulation

George T Harea, Vitali Karaliou, Teryn R Roberts, Jae-Hyek Choi, Brendan M Beely, Leopoldo C Cancio and Andriy I Batchinsky
Perfusion 37 (3) 242 (2022)
https://doi.org/10.1177/0267659121991423

Most High-Intensity Transient Signals Are Not Associated With Specific Surgical Maneuvers

Max H. Twedt, Benjamin D. Hage, James M. Hammel, Ali N. Ibrahimye, Mohanad Shukry, Ahsan Qadeer, Kent M. Eskridge, Edward J. Truemper and Gregory R. Bashford
World Journal for Pediatric and Congenital Heart Surgery 11 (4) 401 (2020)
https://doi.org/10.1177/2150135120909761

The Effects of the Properties of Gases on the Design of Bubble Columns Equipped with a Fine Pore Sparger

Athanasios Kanaris, Theodosios Pavlidis, Ariadni Chatzidafni and Aikaterini Mouza
ChemEngineering 2 (1) 11 (2018)
https://doi.org/10.3390/chemengineering2010011

Clinical evaluation of the air-handling properties of contemporary oxygenators with integrated arterial filter

Marco C. Stehouwer, Kristina R. Legg, Roel de Vroege, Johannes C. Kelder, Erik Hofman, Bastian A. de Mol and Peter Bruins
Perfusion 32 (2) 118 (2017)
https://doi.org/10.1177/0267659116664402

In vitro Air Removal Characteristics of Two Neonatal Cardiopulmonary Bypass Systems: Filtration May Lead to Fractionation of Bubbles

Marco C. Stehouwer, Johannes C. Kelder, Willem van Oeveren and Roel de Vroege
The International Journal of Artificial Organs 37 (9) 688 (2014)
https://doi.org/10.5301/ijao.5000348

Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype

Daniel P. Herbst
The Journal of ExtraCorporeal Technology 46 (3) 239 (2014)
https://doi.org/10.1051/ject/201446239

The Effects of Pressure on Gases in Solution: Possible Insights to Improve Microbubble Filtration for Extracorporeal Circulation

Daniel P. Herbst
The Journal of ExtraCorporeal Technology 45 (2) 94 (2013)
https://doi.org/10.1051/ject/201345094

Development of a New Arterial-Line Filter Design Using Computational Fluid Dynamics Analysis

Daniel P. Herbst and Hani K. Najm
The Journal of ExtraCorporeal Technology 44 (3) 139 (2012)
https://doi.org/10.1051/ject/201244139

In Vitro Evaluation of Gaseous Microemboli Handling of Cardiopulmonary Bypass Circuits with and without Integrated Arterial Line Filters

Saifei Liu, Richard F. Newland, Phillip J. Tully, Sigrid C. Tuble and Robert A. Baker
The Journal of ExtraCorporeal Technology 43 (3) 107 (2011)
https://doi.org/10.1051/ject/201143107

Generation, Detection and Prevention of Gaseous Microemboli during Cardiopulmonary Bypass Procedure

Song Lou, Bingyang Ji, Jinping Liu, Kun Yu and Cun Long
The International Journal of Artificial Organs 34 (11) 1039 (2011)
https://doi.org/10.5301/ijao.5000010

Cannula design reduces particulate and gaseous emboli during cardiopulmonary bypass for coronary revascularization

Adrian L Lata, John W Hammon, Dwight D Deal, David A Stump, Edward H Kincaid and Neal D Kon
Perfusion 26 (3) 239 (2011)
https://doi.org/10.1177/0267659110394905

Clinical Evaluation of the Air Removal Characteristics of an Oxygenator with Integrated Arterial Filter in a Minimized Extracorporeal Circuit

Marco C. Stehouwer, Chris Boers, Roel de Vroege, Johannes C. Kelder, Alaaddin Yilmaz and Peter Bruins
The International Journal of Artificial Organs 34 (4) 374 (2011)
https://doi.org/10.5301/IJAO.2011.7749

In-Vitro Quantification of Gaseous Microemboli in Two Extracorporeal Life Support Circuits

Jeffrey Burnside, Daniel Gomez, Thomas J. Preston, Vincent F. Olshove and Alistair Phillips
The Journal of ExtraCorporeal Technology 43 (3) 123 (2011)
https://doi.org/10.1051/ject/201143123

Air Removal Efficiency of a Venous Bubble Trap in a Minimal Extracorporeal Circuit During Coronary Artery Bypass Grafting

Tamara P.A. Roosenhoff, Marco C. Stehouwer, Roel De Vroege, René P. Butter, Wim‐Jan Van Boven and Peter Bruins
Artificial Organs 34 (12) 1092 (2010)
https://doi.org/10.1111/j.1525-1594.2009.00986.x

Effect of organic surfactant additives on gas holdup in the pseudo-homogeneous regime in bubble columns equipped with fine pore sparger

A.D. Anastasiou, N.A. Kazakis, A.A. Mouza and S.V. Paras
Chemical Engineering Science 65 (22) 5872 (2010)
https://doi.org/10.1016/j.ces.2010.08.011

Consensus Statement: Minimal Criteria for Reporting the Systemic Inflammatory Response to Cardiopulmonary Bypass

R. Clive Landis, John M. Murkin, David A. Stump, Robert A. Baker, Joseph E. Arrowsmith, Filip De Somer, Steven L. Dain, Wojciech B. Dobkowski, John E. Ellis, Florian Falter, Gregory Fischer, John W. Hammon, Richard A. Jonas, Robert S. Kramer, Donald S. Likosky, F. Paget Milsom, Michael Poullis, Edward D. Verrier, Keith Walley and Stephen Westaby
The Heart Surgery Forum 13 (2) E108-A (2010)
https://doi.org/10.1532/HSF98.20101182

In vitro and in vivo evaluation of Dideco’s paediatric cardiopulmonary circuit for neonates weighing less than five kilograms

AS Thiara, V. Eggereide, T. Pedersen, H. Lindberg and AE Fiane
Perfusion 25 (4) 229 (2010)
https://doi.org/10.1177/0267659110375645

Clinical Real‐Time Monitoring of Gaseous Microemboli in Pediatric Cardiopulmonary Bypass

Shigang Wang, Karl Woitas, J. Brian Clark, John L. Myers and Akif Ündar
Artificial Organs 33 (11) 1026 (2009)
https://doi.org/10.1111/j.1525-1594.2009.00910.x

Post-Arterial Filter Gaseous Microemboli Activity of Five Integral Cardiotomy Reservoirs during Venting: An In Vitro Study

Gerard J. Myers, Cheri Voorhees, Rob Haynes and Bob Eke
The Journal of ExtraCorporeal Technology 41 (1) 20 (2009)
https://doi.org/10.1051/ject/200941020

Arterial Line Filters Ranked for Gaseous Micro-Emboli Separation Performance: An In Vitro Study

Jeffrey B. Riley
The Journal of ExtraCorporeal Technology 40 (1) 21 (2008)
https://doi.org/10.1051/ject/200840021

Gaseous Microemboli Detection in a Simulated Pediatric CPB Circuit Using a Novel Ultrasound System

Akemi Miller, Shigang Wang, John L. Myers and Akif Ündar
ASAIO Journal 54 (5) 504 (2008)
https://doi.org/10.1097/MAT.0b013e318186d32a

Microemboli Detection and Classification by Innovative Ultrasound Technology During Simulated Neonatal Cardiopulmonary Bypass at Different Flow Rates, Perfusion Modes, and Perfusate Temperatures

Robert S. Schreiner, Alan R. Rider, John W. Myers, Bingyang Ji, Allen R. Kunselman, John L. Myers and Akif Ündar
ASAIO Journal 54 (3) 316 (2008)
https://doi.org/10.1097/MAT.0b013e31816ecfff

Letters to the Editor

Gary Hay, Timothy A. Dickinson, Jeffrey B. Riley, Jeffrey C. Crowley and Gerard J Myers
The Journal of ExtraCorporeal Technology 39 (1) 55 (2007)
https://doi.org/10.1051/ject/200739055

Bubble columns with fine pore sparger operating in the pseudo-homogeneous regime: Gas hold up prediction and a criterion for the transition to the heterogeneous regime

N.A. Kazakis, I.D. Papadopoulos and A.A. Mouza
Chemical Engineering Science 62 (12) 3092 (2007)
https://doi.org/10.1016/j.ces.2007.03.004

Cardiopulmonary Bypass Management and Neurologic Outcomes: An Evidence-Based Appraisal of Current Practices

Charles W. Hogue, Christopher A. Palin and Joseph E. Arrowsmith
Anesthesia & Analgesia 103 (1) 21 (2006)
https://doi.org/10.1213/01.ANE.0000220035.82989.79

Quantification of Fat Mobilization in Patients Undergoing Coronary Artery Revascularization Using Off-pump and On-pump Techniques

Ahmed Ajzan, Thomas Modine, Prakash Punjabi, Kandeepan Ganeshalingam, Gary Philips and Terence Gourlay
The Journal of ExtraCorporeal Technology 38 (2) 116 (2006)
https://doi.org/10.1051/ject/200638116

In Vitro Evaluation of the Air Separation Ability of Four Cardiovascular Manufacturer Extracorporeal Circuit Designs

Timothy A. Dickinson, Jeffrey B. Riley, Jeffrey C. Crowley and Paul M. Zabetakis
The Journal of ExtraCorporeal Technology 38 (3) 206 (2006)
https://doi.org/10.1051/ject/200638206

First Clinical Experience With the Air Purge Control and Electrical Remote‐controlled Tubing Clamp in Mini Bypass

Rien M.A.J.M. Huybregts, Derk P. Veerman, Alexander B.A. Vonk, Alfred F. Nesselaar, Reggie C.E. Paulus, Deirdre H. Thone‐Passchier, Annette L. Smith and Roel De Vroege
Artificial Organs 30 (9) 721 (2006)
https://doi.org/10.1111/j.1525-1594.2006.00291.x

Effect of perfusionist technique on cerebral embolization during cardiopulmonary bypass

Rosendo A Rodriguez, Kathryn A Williams, Andrei Babaev, Fraser Rubens and Howard J Nathan
Perfusion 20 (1) 3 (2005)
https://doi.org/10.1191/0267659105pf778oa

The use of a mini bypass system (Cobe Synergy) without venous and cardiotomy reservoir in a mitral valve repair: a case report

M AJM Huybregts, R de Vroege, H MT Christiaans, A L Smith and R CE Paulus
Perfusion 20 (2) 121 (2005)
https://doi.org/10.1191/0267659105pf794cr

Gaseous Microemboli and the Influence of Microporous Membrane Oxygenators

Heinz-H. Weitkemper, Bernd Oppermann, Andreas Spilker, Hermann-J. Knobl and Reiner Körfer
The Journal of ExtraCorporeal Technology 37 (3) 256 (2005)
https://doi.org/10.1051/ject/200537256