The Citing articles tool gives a list of articles citing the current article. The citing articles come from EDP Sciences database, as well as other publishers participating in CrossRef Cited-by Linking Program. You can set up your personal account to receive an email alert each time this article is cited by a new article (see the menu on the right-hand side of the abstract page).
Carbon Dioxide Flush of an Integrated Minimized Perfusion Circuit Prior to Priming Prevents Spontaneous Air Release Into the Arterial Line During Clinical Use
Marco C. Stehouwer, Roel de Vroege, Gerard J. F. Hoohenkerk, Frederik N. Hofman, Johannes C Kelder, Bas Buchner, Bastian A. de Mol and Peter Bruins Artificial Organs 41(11) 997 (2017) https://doi.org/10.1111/aor.12909
Versatile minimized system - a step towards safe perfusion
Excessive negative venous line pressures and increased arterial air bubble counts during miniaturized cardiopulmonary bypass: an experimental study comparing miniaturized with conventional perfusion systems
A. Aboud, K. Liebing, J. Borgermann, S. Ensminger, A. Zittermann, A. Renner, K. Hakim-Meibodi and J. Gummert European Journal of Cardio-Thoracic Surgery 45(1) 69 (2014) https://doi.org/10.1093/ejcts/ezt257
Kyriakos Anastasiadis, Polychronis Antonitsis and Helena Argiriadou 73 (2013) https://doi.org/10.1007/978-3-642-32756-8_7
Brain Emboli Distribution and Differentiation During Cardiopulmonary Bypass
Paolo Zanatta, Alessandro Forti, Giuseppe Minniti, Alessandra Comin, Anna Paola Mazzarolo, Mwaba Chilufya, Fabrizio Baldanzi, Enrico Bosco, Carlo Sorbara and Elvio Polesel Journal of Cardiothoracic and Vascular Anesthesia 27(5) 865 (2013) https://doi.org/10.1053/j.jvca.2012.12.022
Kyriakos Anastasiadis, Polychronis Antonitsis and Helena Argiriadou 51 (2013) https://doi.org/10.1007/978-3-642-32756-8_5
Can minimized cardiopulmonary bypass systems be safer?
Do Miniaturized Extracorporeal Circuits Confer Significant Clinical Benefit Without Compromising Safety? A Meta-Analysis of Randomized Controlled Trials
2011 Update to The Society of Thoracic Surgeons and the Society of Cardiovascular Anesthesiologists Blood Conservation Clinical Practice Guidelines
Victor A. Ferraris, Jeremiah R. Brown, George J. Despotis, John W. Hammon, T. Brett Reece, Sibu P. Saha, Howard K. Song, Ellen R. Clough, Linda J. Shore-Lesserson, Lawrence T. Goodnough, C. David Mazer, Aryeh Shander, Mark Stafford-Smith, Jonathan Waters, Robert A. Baker, Timothy A. Dickinson, Daniel J. FitzGerald, Donald S. Likosky and Kenneth G. Shann The Annals of Thoracic Surgery 91(3) 944 (2011) https://doi.org/10.1016/j.athoracsur.2010.11.078
Clinical Evaluation of the Air Removal Characteristics of an Oxygenator with Integrated Arterial Filter in a Minimized Extracorporeal Circuit
Marco C. Stehouwer, Chris Boers, Roel de Vroege, Johannes C. Kelder, Alaaddin Yilmaz and Peter Bruins The International Journal of Artificial Organs 34(4) 374 (2011) https://doi.org/10.5301/IJAO.2011.7749
Hyaluronan Based Heparin Free Coated Open and Closed Extracorporeal Circuits for High Risk Coronary Revascularization
Serdar Gunaydin, Halil Ibrahim Ucar, Tanzer Serter, Kevin McCusker, Gokhan Ozcelik, Nevriye Salman and Ali Cem Yorgancioglu The Journal of ExtraCorporeal Technology 42(4) 286 (2010) https://doi.org/10.1051/ject/201042286
Monitoring Microemboli During Cardiopulmonary Bypass with the EDAC® Quantifier
John E. Lynch, Christopher Wells, Tom Akers, Paul Frantz, Donna Garrett, M. Lance Scott, Lisa Williamson, Barbara Agnew and John K. Lynch The Journal of ExtraCorporeal Technology 42(3) 212 (2010) https://doi.org/10.1051/ject/201042212
Is the Air Handling Capability of the Quadrox D Pump Dependent within an ECMO Circuit? An In Vitro Study
Air Removal Efficiency of a Venous Bubble Trap in a Minimal Extracorporeal Circuit During Coronary Artery Bypass Grafting
Tamara P.A. Roosenhoff, Marco C. Stehouwer, Roel De Vroege, René P. Butter, Wim‐Jan Van Boven and Peter Bruins Artificial Organs 34(12) 1092 (2010) https://doi.org/10.1111/j.1525-1594.2009.00986.x
Post-Arterial Filter Gaseous Microemboli Activity of Five Integral Cardiotomy Reservoirs during Venting: An In Vitro Study
Gaseous Microemboli and the Influence of Microporous Membrane Oxygenators
Heinz-H. Weitkemper, Bernd Oppermann, Andreas Spilker, Hermann-J. Knobl and Reiner Körfer The Journal of ExtraCorporeal Technology 37(3) 256 (2005) https://doi.org/10.1051/ject/200537256