| Issue |
J Extra Corpor Technol
Volume 37, Number 3, September 2005
|
|
|---|---|---|
| Page(s) | 306 - 310 | |
| DOI | https://doi.org/10.1051/ject/200537306 | |
| Published online | 15 September 2005 | |
Scientific Article
The Coronary Baroreflex in Humans
* Yorkshire Heart Centre, Leeds General Infirmary, University of Leeds, Leeds, United Kingdom
† Institute for Cardiovascular Research, University of Leeds, Leeds, United Kingdom
*Address correspondence to K. Kincaid, BSc(Hon), Clinical Perfusion, Leeds General Infirmary, United Leeds Teaching Hospitals, Great George Street, Leeds, United Kingdom LS1 3EX. E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Abstract
Previous studies have identified the presence of coronary baroreceptors in animal models. We set up a study to explore the presence of coronary baroreceptors in humans, which was performed with isolated, graded aortic root perfusion in patients during cardiopulmonary bypass. With ethical approval 12 patients with normal coronary arteries, aged 58–75 (mean 69) years undergoing mitral valve surgery were recruited to the study with informed consent. Those with aortic valve incompetence, coronary, or peripheral artery disease and diabetes mellitus were excluded. They were randomized to have their coronary perfusion pressure set low at 50 mmHg for 90 seconds and then adjusted high to 80 mmHg for 90 seconds (group L–H) or the reverse sequence (group H–L). Average arterial pressure and approximately constant systemic flow over 30-second periods were used to calculate vascular resistance (SVR). The first six experiments followed initiation of cardiopulmonary bypass and aortic clamping but before the delivery of cold blood cardioplegia; the blood temperature for these experiments was kept at 32°C. The remaining six were conducted prior to removal of the aortic cross clamp at 37°C. Coronary sinus blood samples were analyzed to exclude myocardial ischemia. Coronary sinus blood samples showed insignificant variation in oxygen saturation, lactate, and troponin T. Three patients were excluded because of unstable blood pressure. In the (L–H) group SVR reduced in 4 of 4 remaining patients (mean −9.4%, range −3.9 to −19.6%). In the (H–L) group SVR increased in three patients (mean +2.0%, range 1.1 to 3.7%) but decreased in two (−8.9% and −15.8%). These preliminary results, although not statistically different, suggest the presence of coronary baroreceptors in humans. The reflex vascular responses are similar to those previously reported in animal models.
Key words: baroreceptors / coronary artery / blood pressure / coronary pressure / human
Presented at the 43rd International Conference of the American Society of Extra-Corporeal Technology, New Orleans, Louisiana, March 3–6, 2005.
The senior author has stated that authors have reported no material, financial or other relationship with any healthcare-related business or other entity whose products or services are discussed in this paper.
© 2005 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.
