Percutaneous Cardiopulmonary (Bypass) Support in the Cardiac Catheterization Laboratory: A New Application of Perfusion
Department of Interventional Cardiology, Washington Adventist Hospital, Takoma Park, MD
* Address correspondence to: Fayaz A. Shawl, M.D., Director, Interventional Cardiology, Washington Adventist Hospital, 7600 Carroll Avenue, Takoma Park, MD 20912
Percutaneous cardiopulmonary bypass support (PCPS) has been introduced in the catheterization laboratory to support high risk coronary angioplasty, as well as emergencies. We report the safety and feasibility of PCPS in 45 patients. Thirty-seven patients (Group 1) were elective and eight were emergencies (Group 2). Group 1 (ages 41-82) were high risk coronary angioplasty, Group 2 (ages 40-82) were in cardiogenic shock due to myocardial infarction with two in cardiac arrest. Cannulation of femoral artery and vein was with 20 French cannulae. Priming of the system with 1400 ml of Normosol was achieved in 5-7 minutes. Cardiopulmonary bypass was then instituted using the Bard CPS system after full heparinization (300 units per kilogram). Flows ranged from 2.8-5.5 liters per minute (mean-3.8) and pulmonary diastolic pressures were 0-4 mm Hg. Two patients in cardiac arrest regained consciousness while still in ventricular fibrillation or asystole. The activated clotting time ranged from 317-880 seconds (mean=498). Mean bypass time was 37 minutes (range 10-73) in Group 1 and 66 minutes (range 44-120) in Group 2. Total infusion volume of Normosol during and prior to termination of bypass was 0-2500 cc (mean=338). There were no procedural complications associated with PCPS. We conclude that PCPS can be used safely in selected patients who are considered high risk for PICA or acute MI complicated by shock or cardiac arrest. This technology adds a new dimension in perfusion in the catheterization laboratory.
Key words: PTCA / cardiac catheterization / cardiopulmonary support / extracorporeal circulation
© 1989 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.