Vacuum-Assisted Venous Drainage: To Air or Not To Air, That Is the Question. Has the Bubble Burst?
Clinical Perfusion, Cardiothoracic Unit, Green Lane Hospital, Auckland, 1005, New Zealand
* Address correspondence to: Timothy Willcox, CCP, Chief Perfusionist, Green Lane Hospital, Auckland 1005, New Zealand
Received:
August
2001
Accepted:
January
2002
Assisted venous drainage is a recent development in cardiopulmonary bypass (CPB) and was introduced to overcome limitations in achieving adequate blood flow through small diameter cannulas used in minimally invasive surgery. The more common application, vacuum assisted venous drainage (VAVD) is now widely used in both adult and pediatric CPB. During a clinical investigation into pharmacological cerebral protection at Green Lane Hospital, we repeatedly observed evidence of emboli in the right common carotid artery following both entrainment of air into the venous line, and also, reductions in the blood level of the hard-shell venous reservior. We subsequently embarked upon a series of in vitro experiments designed to identify sources of emboli from the CPB circuit, and to evaluate the ability of CPB circuit components to remove air entrained into the venous line under conditions of both gravity and vacuum assisted venous drainage. Initial experiments revealed design features of certain hard-shell venous reservoirs that generated gaseous emboli. In further studies using adult circuits, entrainment of air into the venous line under conditions of conventional gravity venous drainage resulted in emboli distal to the arterial filter. When these studies were repeated using VAVD, arterial line emboli increased eight to tenfold. Initial experiments with a pediatric circuit showed similar findings. Cerebral emboli during CPB have been positively correlated with increasing neurocognitive deficits. The application of VAVD has been employed clinically without any significant redesign of the components of the CPB circuit. While VAVD may be efficacious in certain scenarios, a thorough understanding of its influence on CPB is essential. Advantages must be balanced against potential hazards. The safe use of VAVD necessitates refinement of perfusion techniques, judicious choice of application, and further development of the CPB circuit.
Key words: cardiopulmonary bypass / vacuum-assisted venous drainage (VAVD) / emboli
© 2002 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.