Issue |
J Extra Corpor Technol
Volume 36, Number 3, September 2004
|
|
---|---|---|
Page(s) | 250 - 254 | |
DOI | https://doi.org/10.1051/ject/2004363250 | |
Published online | 08 August 2023 |
Database Review of Possible Factors Influencing Point-of-Care Platelet Gel Manufacture
1
Department Of General Anesthesiology, Cleveland Clinic Foundation, Cleveland, Ohio
2
Perioperative Blood Management Consultants, Marietta, Georgia
* Address correspondence to: Jonathan H. Waters, MD, Magee Women’s Hospital, 300 Halket St., Suite 3510, Pittsburgh, PA 15213
The application of autologous platelet gel (APG) to surgical wounds has been advocated during the last 10 years to speed bone and wound healing, minimize infection, and modify postoperative pain. There are few data available to confirm these claims. Prior to organized study, consistency and agreement in manufacture of the APG is needed. In this study, an attempt is made to isolate factors that are important in developing a consistent gel. A database review was performed to determine factors that affect PG quality and function. Quality was assessed by platelet count and fibrinogen concentration, whereas function was assessed by an arbitrary scale of gelling, in which a “1” was equal to a soup texture, “3” equal to a “Jell-O” consistency, whereas a grade of “2” was somewhere in between. Data specific to the blood draw and platelet-rich plasma sequestration were collected. Two hundred and sixty cases of APG production were reviewed. The volume of blood drawn was dependent on the machine used. Gelling of the APG was independent of platelet count and fibrinogen concentration. Gels that were rated soupy had an average platelet count of 540 K/μL ± 327 K/μL and a fibrinogen concentration of 225 mg/dL ± 76 mg/dL whereas a firm gel had an average platelet count of 486 K/μL ± 264 K/μL and a fibrinogen concentration of 229 mg/dL ± 78 mg/dL. The manner in which the blood was drawn along with the site from which the blood was drawn influenced the platelet concentration of the platelet-rich plasma. Optimal platelet counts were obtained when blood was drawn from a peripheral vein and sequestration was performed with the Medtronic Sequestra or the Medtronic Magellan. Ultimate gelling of PG is independent of fibrinogen and platelet concentrations. This work suggests a need for further research into the manufacture of APG.
Key words: platelet gel / quality / fibrinogen concentration / fibrin glue
© 2004 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.