Issue |
J Extra Corpor Technol
Volume 37, Number 4, December 2005
|
|
---|---|---|
Page(s) | 355 - 359 | |
DOI | https://doi.org/10.1051/ject/200537355 | |
Published online | 15 December 2005 |
Scientific Article
The Future of the Perfusion Record: Automated Data Collection vs. Manual Recording
* Ashford Hospital, Ashford, South Australia, Australia
† Flinders Medical Centre Bedford Park, South Australia, Australia
‡ Flinders University, Bedford Park, South Australia, Australia
Address correspondence to: Robert A. Baker, PhD, Dip Perf, CCP, Dept. of Cardiac and Thoracic Surgery, Flinders Medical Center, Bedford Park, South Australia, Australia, 5042. E-mail: rob.Baker@flinders.edu.aup
The perfusion record, whether manually recorded or computer generated, is a legal representation of the procedure. The handwritten perfusion record has been the most common method of recording events that occur during cardiopulmonary bypass. This record is of significant contrast to the integrated data management systems available that provide continuous collection of data automatically or by means of a few keystrokes. Additionally, an increasing number of monitoring devices are available to assist in the management of patients on bypass. These devices are becoming more complex and provide more data for the perfusionist to monitor and record. Most of the data from these can be downloaded automatically into online data management systems, allowing more time for the perfusionist to concentrate on the patient while simultaneously producing a more accurate record. In this prospective report, we compared 17 cases that were recorded using both manual and electronic data collection techniques. The perfusionist in charge of the case recorded the perfusion using the manual technique while a second perfusionist entered relevant events on the electronic record generated by the Stockert S3 Data Management System/Data Bahn (Munich, Germany). Analysis of the two types of perfusion records showed significant variations in the recorded information. Areas that showed the most inconsistency included measurement of the perfusion pressures, flow, blood temperatures, cardioplegia delivery details, and the recording of events, with the electronic record superior in the integrity of the data. In addition, the limitations of the electronic system were also shown by the lack of electronic gas flow data in our hardware. Our results confirm the importance of accurate methods of recording of perfusion events. The use of an automated system provides the opportunity to minimize transcription error and bias. This study highlights the limitation of spot recording of perfusion events in the overall record keeping for perfusion management.
Key words: electronic data / computerized data collection / data accuracy / record keeping / cardiopulmonary bypass
© 2005 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.