Issue |
J Extra Corpor Technol
Volume 40, Number 4, December 2008
|
|
---|---|---|
Page(s) | 229 - 233 | |
DOI | https://doi.org/10.1051/ject/200840229 | |
Published online | 15 December 2008 |
Abstract
Effects of Modified Ultrafiltration on Coagulation as Measured by the Thromboelastograph
* University of Wisconsin Hospital and Clinics, Madison, Wisconsin
† University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
‡ University of Nebraska Medical Center, Clinical Perfusion Education, Omaha, Nebraska
Address correspondence to: Thomas G. Steffens, MPS, CCP, LP, University of Wisconsin Hospital and Clinics, 600 Highland Avenue, E5/304A, 3212, Madison, WI 53792. E-mail: tsteffens@uwhealth.org
Hemodilution during cardiopulmonary bypass (CPB) continues to be a cause of morbidity associated with coagulation dysfunction, bleeding, and allogeneic blood transfusion. Clot formation and strength have been shown to impact bleeding and transfusions. Strategies to reduce hemodilution may be negated based on the course of the cardiac procedure itself. Modified ultrafiltration (MUF) is commonly used in pediatric cardiac surgery; however, it is not well accepted in adult surgery. This study aimed to evaluate clot formation and strength, bleeding, and transfusions in adult subjects undergoing MUF. Nineteen subjects having primary coronary artery bypass, aortic, or mitral valve surgeries were recruited and randomized to having MUF (n = 10) or no-MUF (n = 9) performed after the termination of CPB. Five time points for data collection were designated: T1, baseline/induction; T2, termination CPB; T3, post-MUF; T4, post-protamine; T5, 24 hours postoperative. Subjects randomized to MUF had 1505 ± 15.8 mL of effluent removed, and no-MUF subjects had the CPB remnants processed with a cell salvage device. There was no statistical difference seen in 24-hour chest tube output, thromboelastograph values, or allogeneic transfusions at any time point between MUF and no-MUF subjects. There was a significant difference between MUF and no-MUF in the number of autologous cell salvage units processed (1.3 ± .48 vs. 2.9 ± .78, p = .0013) and end of procedure net fluid balance (+2003 ± 1211 vs. +4194 ± 1276 mL, p = .001), respectively. Estimated plasma loss from the cell salvage device was 477.6 mL greater in the no-MUF group. In primary adult cardiac procedures, MUF did not change coagulation values as measured by thromboelastography, number of allogeneic unit transfusions, or chest tube output at 24 hours postoperatively. There was a significant difference in autologous cell salvage units processed and end of procedure net fluid balance that benefited MUF subjects.
Key words: cardiopulmonary bypass / modified ultrafiltration / thromboelastograph
© 2008 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.