Neonatal Extracorporeal Membrane Oxygenation Devices, Techniques and Team Roles: 2011 Survey Results of the United States’ Extracorporeal Life Support Organization Centers
Address correspondence to: Scott Lawson, MS, CCP, Department of Circulatory Support, Children’s Hospital Colorado, 13123 East 16th Avenue, Box 100, Aurora, CO 80045. E-mail: Scott.Lawson@childrenscolorado.org
Received:
1
July
2011
Accepted:
1
December
2011
In early 2011, surveys of active Extracorporeal Life Support Organization (ELSO) centers within the United States were conducted by electronic mail regarding neonatal Extracorporeal Membrane Oxygenation (ECMO) equipment and professional staff. Seventy-four of 111 (67%) U.S. centers listed in the ELSO directory as neonatal centers responded to the survey. Of the responding centers, 53% routinely used roller pumps for neonatal ECMO, 15% reported using centrifugal pumps and 32% reported using a combination of both. Of the centers using centrifugal pumps, 51% reported that they do not use a compliance bladder in the circuit. The majority (95%) of roller pump users reported using a compliance bladder and 97% reported using Tygon® S-97-E tubing in the raceway of their ECMO circuits. Silicone membrane oxygenators were reportedly used by 25% of the respondents, 5% reported using micro-porous hollow fiber oxygenators (MPHF), 70%reported using polymethylpentene (PMP) hollow fiber oxygenators and 5% reported using a combination of the different types. Some form of in-line blood monitoring was used by 88% of the responding centers and 63% of responding centers reported using a circuit surface coating. Anticoagulation monitoring via the activated clotting time (ACT) was reported by 100% of the reporting centers. The use of extracorporeal cardiopulmonary resuscitation (ECPR) was reported by 53% of the responding centers with 82% of those centers using a crystalloid primed circuit to initiate ECPR. A cooling protocol was used by 77% of the centers which have an ECPR program. When these data are compared with surveys from 2002 and 2008 it shows that the use of silicone membrane oxygenators continues to decline, the use of centrifugal pumps continues to increase and ECMO personnel continues to be comprised of multidisciplinary groups of dedicated allied health care professionals.
Key words: ECMO / equipment / survey / devices
© 2011 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.