Open Access
Table 2
Pre- and intra-procedural data.
Procedures | Ventricular tachycardia ablation (n = 10) |
---|---|
Pre-CPB hematocrit (%) | 36.7 ± 1.9 |
Pre-CPB Hb (g/dL) | 11.9 ± 1.8 |
CPB time (min) | 140 ± 18 |
Perioperative CVP target (mmHg) on MiECC without Volume management | 15 ± 4 |
Perioperative ACT (s) | 400 ± 60 |
Hb (g/dL) during CPB | 9.78 ± 1.19 |
Mean arterial pressure (mmHg) before volume management | 100 ± 18 |
Blood flow (L/min) before volume management | 1.5 ± 0.6 |
Mean arterial pressure (mmHg) after volume management | 65 ± 13 |
CVP target (mmHg) after volume management in MiECC | 4 ± 3 |
Blood flow (L/min) after volume management | 5 ± 0.7 |
Values are presented as n (%) or mean ± standard deviation.
CVP: Central Venous Pressure; CPB: cardiopulmonary bypass; Hb: hemoglobin; MiECC: minimally invasive extracorporeal circulation.