Table 1
Settings, vital signs and blood gases during VV-ECMO run.
| 1st hour | 5th hour | 10th hour | |
|---|---|---|---|
| Blood Flow (LPM) | 2.6 | 3.7 | 3.7 |
| Pump speed (RPM) | 1500 | 2460 | 2460 |
| Sweep (LPM) | 2 | 1 | 1 |
| Patient SaO2 | 100 | 100 | 98 |
| Patient PaO2 (mmHg) | 311 | 177 | 108 |
| Patient PaCO2 (mmHg) | 35 | 35 | 35 |
| Patient pH | 7.46 | 7.47 | 7.46 |
| Patient Lactate (mmol/L) | 3.1 | 1.9 | 1.1 |
| ACT | 225 | 189 | 186 |
| Heparin infusion (IU/kg/hr) | 50 | 50 | 50 |
Abrev. LPM: liters/min; RPM: revolutions/min; FiO2: inspired fraction of oxygen; ACT: activated time of coagulation.