Free Access
Issue |
J Extra Corpor Technol
Volume 40, Number 1, March 2008
|
|
---|---|---|
Page(s) | 57 - 60 | |
DOI | https://doi.org/10.1051/ject/200840057 | |
Published online | 15 March 2008 |
- Jatlow P. Point of care laboratory testing in the emergency department. Am J Clin Pathol. 1993;100:59. [Google Scholar]
- Parvin CA, Lo SF, Deuser SM, Weaver LG, Lewis LM, Scott MG. Impact of point-of-care testing on patients’ length of stay in a large emergency department. Clin Chem. 1996;42:711–7. [CrossRef] [PubMed] [Google Scholar]
- Kendall J, Reeves B, Clancy M. Point of care testing: randomised controlled trial of clinical outcome. BMJ. 1998;316:1052–7. [CrossRef] [PubMed] [Google Scholar]
- Gilbert HC, Szokol JW. Point of care technologies. Int Anesthesiol Clin. 2004;42:73–94. [CrossRef] [PubMed] [Google Scholar]
- Vos G, Engel M, Ramsay G, van Waardenburg D. Point-of-care blood analyzer during the interhospital transport of critically ill children. Eur J Emerg Med. 2006;13:304–7. [CrossRef] [PubMed] [Google Scholar]
- Connelly NR, Magee M, Kiessling B. The use of the i-STAT portable analyzer in patient undergoing cardiopulmonary bypass. J Clin Monit Comput. 1996;12:311–5. [CrossRef] [PubMed] [Google Scholar]
- Sediame S, Zerah-Lancner F, d’Ortho MP, Adnot S, Harf A. Accuracy of the i-STAT bedside blood gas analyser. Eur Respir J. 1999; 14:214–7. [CrossRef] [Google Scholar]
- Murthy JN, Hicks JM, Soldin SJ. Evaluation of i-STAT portable clinical analyzer in a neonatal and pediatric intensive care unit. Clin Biochem. 1997;30:385–9. [CrossRef] [Google Scholar]
- Mock T, Morrison D, Yatscoff R. Evaluation of the i-STAT system: a portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea, glucose and hematocrit. Clin Biochem. 1995; 28:187–92. [CrossRef] [Google Scholar]
- Jacobs E, Vadasdi E, Sarkozi L, Colman N. Analytical evaluation of i-STAT portable clinical analyzer and use by nonlaboratory healthcare professionals. Clin Chem. 1993;39:1069–74. [CrossRef] [PubMed] [Google Scholar]
- Bingham D, Kendall J, Clancy M. The portable laboratory: an evaluation of the accuracy and reproducibility of i-STAT. Ann Clin Biochem. 1999;36:66–71. [CrossRef] [PubMed] [Google Scholar]
- Pidetcha P, Ornvichian S, Chalachiva S. Accuracy and precision of the i-STAT portable clinical analyzer: an analytical point of view. J Med Assoc Thai. 2000;83:445–50. [Google Scholar]
- Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–10. [CrossRef] [Google Scholar]
- Papadea C, Foster J, Grant S, et al. Evaluation of the i-STAT portable clinical analyzer for point-of-care blood testing in the intensive care units of a university children’s hospital. Ann Clin Lab Sci. 2002; 32:231–43. [Google Scholar]
- Steinfelder-Visscher J, Weerwind PW, Teerenstra S, Brouwer MH. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass. Perfusion. 2006;21:33–7. [CrossRef] [PubMed] [Google Scholar]
- Steinfelder-Visscher J, Weerwind PW, Teerenstra S, Pop GA, Brouwer RM. Conductivity-based hematocrit measurement during cardiopulmonary bypass. J Clin Monit Comput. 2007;21:7–12. [CrossRef] [PubMed] [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.