Free Access
Issue |
J Extra Corpor Technol
Volume 44, Number 2, June 2012
|
|
---|---|---|
Page(s) | 53 - 59 | |
DOI | https://doi.org/10.1051/ject/201244053 | |
Published online | 15 June 2012 |
- Segers P, Heida JF, de Vries I, Maas C, Boogaart AJ, Eilander S. Clinical evaluation of nine hollow-fibre membrane oxygenators. Perfusion. 2001;16:95–106. [CrossRef] [PubMed] [Google Scholar]
- Chukwuemeka AO, Turtle MRJ, Trivedi UH, Venn GE, Chambers DJ. A clinical evaluation of platelet function, haemolysis and oxygen transfer during cardiopulmonary bypass comparing the Quantum HF-6700 to the HF-5700 hollow fibre membrane oxygenator. Perfusion. 2000;15:479–484. [CrossRef] [PubMed] [Google Scholar]
- Noora J, Lamy A, Smith KM, et al. The effect of oxygenator membranes on blood: A comparison of two oxygenators in open-heart surgery. Perfusion. 2003;18:313–320. [CrossRef] [PubMed] [Google Scholar]
- Ündar A, Owens WR, McGarry MC, et al. Comparison of hollow-fiber membrane oxygenators in terms of pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass in neonates. Perfusion. 2005;20:135–138. [CrossRef] [PubMed] [Google Scholar]
- Hoel TN, Videm V, Baksaas ST, Mollnes TE, Brosstad F, Svennevig JL. Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery. Perfusion. 2004;19:177–184. [CrossRef] [PubMed] [Google Scholar]
- Dickinson TA, Riley JB, Crowley JC, Zabetakis PM. In vitro evaluation of the air separation ability of four cardiovascular manufacturer extra-corporeal circuit designs. J Extra Corpor Technol. 2006;38:206–213. [Google Scholar]
- Myers GJ, Voorhees C, Haynes R, Eke B. Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: An in vitro study. J Extra Corpor Technol. 2009;41:20–27. [Google Scholar]
- Preston TJ, Gomez D, Olshove VF, Phillips A, Galantowicz M. Clinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population. J Extra Corpor Technol. 2009;41:226–230. [CrossRef] [EDP Sciences] [PubMed] [Google Scholar]
- Liu S, Newland RF, Tully PJ, Tuble SC, Baker RA. In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters. J Extra Corpor Technol. 2011;43:107–114. [CrossRef] [EDP Sciences] [PubMed] [Google Scholar]
- Newling R, Morris R. SMARxT tubing presents an increased risk of disconnection during extracorporeal circulation. J Extra Corpor Technol. 2005;37:400–401. [CrossRef] [EDP Sciences] [PubMed] [Google Scholar]
- Ottens J, Baker RA, Sanderson AJ, Newland RF. Disconnection of Cobe SMARxT® tubing from the venous outlet of the Terumo Capiox® SX25RX oxygenator during cardiopulmonary bypass. J Extra Corpor Technol. 2010;42:153–157. [CrossRef] [EDP Sciences] [PubMed] [Google Scholar]
- Newland RF, Sanderson AJ, Baker RA. Accuracy of temperature measurement in the cardiopulmonary bypass circuit. J Extra Corpor Technol. 2005;37:32–37. [CrossRef] [EDP Sciences] [PubMed] [Google Scholar]
- Salah M, Sutton R, Tsarovsky G, Djuric M. Temperature inaccuracies during cardiopulmonary bypass. J Extra Corpor Technol. 2005;37:38–42. [CrossRef] [EDP Sciences] [PubMed] [Google Scholar]
- Potger KC, McMillan D. In vitro validation of the Affinity NT oxygenator arterial outlet temperatures. J Extra Corpor Technol. 2005;37:207–212. [CrossRef] [EDP Sciences] [PubMed] [Google Scholar]
- Shann KG, Likosky DS, Murkin JM, et al. An evidence-based review of the practice of cardiopulmonary bypass in adults: A focus on neurologic injury, glycemic control, hemodilution, and the inflammatory response. J Thorac Cardiovasc Surg. 2006;132: 283–290. [CrossRef] [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.