Free Access
Issue |
J Extra Corpor Technol
Volume 51, Number 2, June 2019
|
|
---|---|---|
Page(s) | 73 - 77 | |
DOI | https://doi.org/10.1051/ject/201951073 | |
Published online | 15 June 2019 |
- Weitkemper HH, Spilker A, Knobl HJ, et al. The heater-cooler unit–a conceivable source of infection. J Extra Corpor Technol. 2002;34:276–80. [CrossRef] [EDP Sciences] [PubMed] [Google Scholar]
- Sax H, Bloemberg G, Hasse B, et al. Prolonged outbreak of Mycobacterium chimaera infection after open-chest heart surgery. Clin Infect Dis. 2015;61:67–75. [CrossRef] [PubMed] [Google Scholar]
- Balsam LB, Louie E, Hill F, et al. Mycobacterium chimaera left ventricular assist device infections. J Card Surg. 2017;32:402–4. [CrossRef] [PubMed] [Google Scholar]
- Chand M, Lamagni T, Kranzer K, et al. Insidious risk of severe Mycobacterium chimaera infection in cardiac surgery patients. Clin Infect Dis. 2017;64:335–42. [CrossRef] [PubMed] [Google Scholar]
- Hamad R, Noly PE, Perrault LP, et al. Mycobacterium chimaera infection after cardiac surgery: First Canadian outbreak. Ann Thorac Surg. 2017;104:e43–5. [CrossRef] [PubMed] [Google Scholar]
- Kohler P, Kuster SP, Bloemberg G, et al. Healthcare-associated prosthetic heart valve, aortic vascular graft, and disseminated Mycobacterium chimaera infections subsequent to open heart surgery. Eur Heart J. 2015;36:2745–53. [CrossRef] [PubMed] [Google Scholar]
- Scriven JE, Scobie A, Verlander NQ, et al. Mycobacterium chimaera infection following cardiac surgery in the United Kingdom: Clinical features and outcome of the first 30 cases. Clin Microbiol Infect. 2018;24:1164–70. [CrossRef] [PubMed] [Google Scholar]
- US Food and Drug Administration. Update: Availability of Deep-Cleaning Service of Certain LivaNova PLC (formerly Sorin Group Deutschland GmbH) Stockert 3T Heater-Cooler Systems in the US: FDA Safety Communication. 2018 Available at: https://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm610394.htm. Accessed June 12, 2018 [cited 2018 Jul]. [Google Scholar]
- Barker TA, Dandekar U, Fraser N, et al. Minimising the risk of Mycobacterium chimaera infection during cardiopulmonary bypass by the removal of heater-cooler units from the operating room. Perfusion. 2017;33:264–9. [Google Scholar]
- Sommerstein R, Ruegg C, Kohler P, et al. Transmission of Mycobacterium chimaera from heater-cooler units during cardiac surgery despite an ultraclean air ventilation system. Emerg Infect Dis. 2016;22:1008–13. [CrossRef] [PubMed] [Google Scholar]
- Stammers AH, Riley JB The heater-cooler as a source of infection from nontuberculous mycobacteria. J Extra Corpor Technol. 2016;48:55–9. [CrossRef] [EDP Sciences] [PubMed] [Google Scholar]
- Gotting T, Klassen S, Jonas D, et al. Heater-cooler units: Contamination of crucial devices in cardiothoracic surgery. J Hosp Infect. 2016;93:223–8. [CrossRef] [PubMed] [Google Scholar]
- Tortoli E, Rindi L, Garcia MJ, et al. Proposal to elevate the genetic variant MAC-A, included in the Mycobacterium avium complex, to species rank as Mycobacterium chimaera sp. nov. Int J Syst Evol Microbiol. 2004;54:1277–85. [CrossRef] [PubMed] [Google Scholar]
- Wallace RJJr, Iakhiaeva E, Williams MD, et al. Absence of Mycobacterium intracellulare and presence of Mycobacterium chimaera in household water and biofilm samples of patients in the United States with Mycobacterium avium complex respiratory disease. J Clin Microbiol. 2013;51:1747–52. [CrossRef] [PubMed] [Google Scholar]
- Walker J, Moore G, Collins S, et al. Microbiological problems and biofilms associated with Mycobacterium chimaera in heater-cooler units used for cardiopulmonary bypass. J Hosp Infect. 2017;96:209–20. [CrossRef] [PubMed] [Google Scholar]
- Kanamori H, Weber DJ, Rutala WA Healthcare outbreaks associated with a water reservoir and infection prevention strategies. Clin Infect Dis. 2016;62:1423–35. [CrossRef] [PubMed] [Google Scholar]
- Kuehl R, Banderet F, Egli A, et al. Different types of heater-cooler units and their risk of transmission of Mycobacterium chimaera during open-heart surgery: Clues from device design. Infect Control Hosp Epidemiol. 2018;39:834–40. [CrossRef] [PubMed] [Google Scholar]
- Haller S, Holler C, Jacobshagen A, et al. Contamination during production of heater-cooler units by Mycobacterium chimaera potential cause for invasive cardiovascular infections: Results of an outbreak investigation in Germany, April 2015 to February 2016. Euro Surveill. 2016;28:21. doi: 10.2807/1560-7917.ES.2016.21.17.30215. [Google Scholar]
- Abdou AA, Budaiwi IM Comparison of thermal conductivity measurements of building insulation materials under various operating temperatures. J Buil Phys. 2005;29:171–84. [CrossRef] [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.