Free Access
Issue |
J Extra Corpor Technol
Volume 53, Number 2, June 2021
|
|
---|---|---|
Page(s) | 130 - 136 | |
DOI | https://doi.org/10.1051/ject/202153130 | |
Published online | 15 June 2021 |
- Albrecht M, Gauthier RL, Belani K, et al. . Forced-air warming blowers: An evaluation of filtration adequacy and airborne contamination emissions in the operating room. Am J Infect Contr. 2011;39:321–8. [CrossRef] [Google Scholar]
- Aliabadi AA, Rogak SN, Bartlett KH, et al. . Preventing airborne disease transmission: Review of methods for ventilation design in health care facilities. Adv Prev Med. 2011;2011:124064. [CrossRef] [Google Scholar]
- Andersson AE, Bergh I, Karlsson J, et al. . Traffic flow in the operating room: An explorative and descriptive study on air quality during orthopedic trauma implant surgery. Am J Infect Contr. 2012;40:750–5. [CrossRef] [Google Scholar]
- ASHRAE. Ventilation of health care facilities. Atlanta, GA: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. ANSI/ASHRAE/ASHE Standard 170-2017: 1–42. [Google Scholar]
- CDC. Guidelines for Environmental Infection Control in Health-Care Facilities. Atlanta, GA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention. 2003:132–9. [Google Scholar]
- Eames I, Shoaib D, Klettner CA, et al. . Movement of airborne contaminants in a hospital isolation room. J R Soc Interf. 2009;6(Suppl 6):S757–66. [Google Scholar]
- FDA. Nontuberculous Mycobacterium Infections Associated with Heater-Cooler Devices: FDA Safety Communication. 2015. [Google Scholar]
- Griffiths WD., Bennett A, Speight S, et al. . Determining the performance of a commercial air purification system for reducing airborne contamination using model micro-organisms: A new test methodology. J Hosp Infect. 2005;61:242–7. [CrossRef] [PubMed] [Google Scholar]
- Kakwani RG, Yohannan D, Wahab KH. The effect of laminar air-flow on the results of Austin-Moore hemiarthroplasty. Injury. 2007;38:820–3. [CrossRef] [PubMed] [Google Scholar]
- Kuehl R, Banderet F, Egli A, et al. . Different types of heater-cooler units and their risk of transmission of Mycobacterium chimaera during open-heart surgery: Clues from device design. Infect Control Hosp Epidemiol. 2018;39:834–40. [CrossRef] [PubMed] [Google Scholar]
- Ogunremi T, Taylor G, Johnston L, et al. . Mycobacterium chimaera infections in post-operative patients exposed to heater-cooler devices: An overview. Can Comm Dis Rep. 2017;43:107–13. [CrossRef] [Google Scholar]
- van Doremalen N, Morris DH, Holbrook MG, et al. . Aerosol and surface stability of HCoV-19 (SARS-CoV-2) compared to SARS-CoV-1. N Engl J Med. 2020;382:1564–1567. [CrossRef] [PubMed] [Google Scholar]
- Reed M, Kimberger O, McGovern PD, et al. . Forced-air warming design: Evaluation of intake filtration, internal microbial buildup, and airborne-contamination emissions. Am Assoc Nurse Anesth. 2013;81:275–80. [Google Scholar]
- Rezapoor M, Alvand A, Jacek E, et al. . Operating room traffic increases aerosolized particles and compromises the air quality: A simulated study. J Arthroplasty. 2018;33:851–5. [CrossRef] [PubMed] [Google Scholar]
- Rosemurgy A, Whitaker J, Luberice K, et al. . Cost-benefit analysis of reducing surgical site infections. Am Surg. 2018;84:254–61. [CrossRef] [PubMed] [Google Scholar]
- Singh S, Reddy S, Shrivastava R Does laminar air flow make a difference to the infection rates for lower limb arthroplasty: A study using the national joint registry and local surgical site infection data for two hospitals with and without laminar air flow. Eur J Orthop Surg Traumatol. 2017;27:261–5. [CrossRef] [PubMed] [Google Scholar]
- Stauning MT, Bediako-Bowan A, Andersen LPet al. . Traffic flow and microbial air contamination in operating rooms at a major teaching hospital in Ghana. J Hosp Infect. 2018;99:263–70. [CrossRef] [PubMed] [Google Scholar]
- Klingenberg S. Smoke studies: Clearing the mystery of air flow visualization. J Validation Technol. 2010:11–7. [Google Scholar]
- Wing’s Testing & Balancing Company, Inc. 94 North Branford Road, Suite 1. Branford, CT. [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.