The citing articles come from EDP Sciences database, as well as other publishers participating in CrossRef Cited-by Linking Program. You can set up your personal account to receive an email alert each time this article is cited by a new article (see the menu on the right-hand side of the abstract page).

Cited article:

Spectrum Medical Quantum or Terumo CDI 500: Which Device Measures Hemoglobin and Oxygen Saturation Most Accurately When Compared to a Benchtop Blood Analyzer?

James A. Reagor, Zhiqian Gao and James S. Tweddell
The Journal of ExtraCorporeal Technology 53 (3) 181 (2021)
https://doi.org/10.1051/ject/202153181

Ex vivo models for research in extracorporeal membrane oxygenation: a systematic review of the literature

Maximilian Valentin Malfertheiner, Lars Mikael Broman, Leen Vercaemst, Mirko Belliato, Anna Aliberti, Matteo Di Nardo, Justyna Swol, Nicholas Barrett, Federico Pappalardo, Jan Bělohlávek, Fabio Silvio Taccone, Jonathan Edward Millar, Lachlan Crawford, Roberto Lorusso, Jacky Y Suen and John F Fraser
Perfusion 35 (1_suppl) 38 (2020)
https://doi.org/10.1177/0267659120907439

Continuous monitoring of membrane lung carbon dioxide removal during ECMO: experimental testing of a new volumetric capnometer

Alice Montalti, Mirko Belliato, Sandro Gelsomino, Sandro Nalon, Francesco Matteucci, Orlando Parise, Monique de Jong, Maged Makhoul, Daniel M Johnson and Roberto Lorusso
Perfusion 34 (7) 538 (2019)
https://doi.org/10.1177/0267659119833233

The Norwood Stage 1 procedure - conduct of perfusion: 2017 Survey results from NPC-QIC member institutions

James A. Reagor, Sean Clingan, Bradley T. Kulat, Gregory S. Matte, Jordan Voss and James S. Tweddell
Perfusion 33 (8) 667 (2018)
https://doi.org/10.1177/0267659118781173

Staffing, Equipment, Monitoring Considerations for Extracorporeal Membrane Oxygenation

David C. Fitzgerald, Edward M. Darling and Monika F. Cardona
Critical Care Clinics 33 (4) 863 (2017)
https://doi.org/10.1016/j.ccc.2017.06.008

Accuracy of the Spectrum Medical M4 and Terumo CDI 500 compared to the Radiometer ABL90 FLEX benchtop blood analyzer

James A. Reagor, Zhiqian Gao, John P. Lombardi, Barbara B. Millin, James S. Tweddell and David S. Cooper
Perfusion 32 (7) 523 (2017)
https://doi.org/10.1177/0267659117702710

Malfunction of the Extracorporeal Circulation System: Case Report

Carlos Eduardo David de Almeida, Antônio Roberto Carraretto, Erick Freitas Curi, Louisie Marcelle da Silva Almeida Marques and Roberta Eleni Monteiro Abatti
Brazilian Journal of Anesthesiology 61 (6) 777 (2011)
https://doi.org/10.1016/S0034-7094(11)70087-3

Assessment of a continuous blood gas monitoring system in animals during circulatory stress

Sandro Gelsomino, Roberto Lorusso, Ugolino Livi, Stefano Romagnoli, Salvatore Mario Romano, Rocco Carella, Fabiana Lucà, Giuseppe Billè, Francesco Matteucci, Attilio Renzulli, Gil Bolotin, Giuseppe De Cicco, Pierluigi Stefàno, Jos Maessen and Gian Franco Gensini
BMC Anesthesiology 11 (1) (2011)
https://doi.org/10.1186/1471-2253-11-1

In Vitro Comparison of the New In-Line Monitor BMU 40 versus a Conventional Laboratory Analyzer

F. Oliver Grosse, David Holzhey, Volkmar Falk, et al.
The Journal of ExtraCorporeal Technology 42 (1) 61 (2010)
https://doi.org/10.1051/ject/201042061

Clinical evaluation of the new BMU 40 in-line blood analysis monitor

Jan Schaarschmidt, Joerg Seeburger, Michael A. Borger, F. Oliver Grosse, Klaus Kraemer and Friedrich W. Mohr
Perfusion 24 (4) 277 (2009)
https://doi.org/10.1177/0267659109350935