Evaluation of the Hemobag: A Novel Ultrafiltration System for Circuit Salvage
SUNY–Upstate Medical University, Syracuse, New York
* Address correspondence to: Edward Darling, CCP, Upstate Medical University, 750 East Adams Street, Syracuse, NY 13210. E-mail: darlinge@upstate.edu
Following termination of bypass, the CPB circuit contains a significant volume of diluted blood. Various methods have been used to salvage this blood, including direct transfusion or centrifugation /washing of the circuit volume. These techniques produce a reinfusion product that is either dilute or free of plasma proteins. The purpose of this study is to evaluate the Hemobag ultrafiltration system, which may overcome these limitations. Yorkshire pigs (n = 4, ∼40 kg) were placed on CPB (prime volume 1.5 L) for 60 min. Following CPB, control blood samples (Pre) were collected from the circuit. The circuit contents were then transferred into a Hemobag and processed. Blood samples (post) were then collected from the Hemobag. Pre- and post-samples were analyzed and compared using a Studen’s t-test. Parameters that were significantly different (p < .05) pre-Hemobag versus post-Hemobag were as follows: hematocrit 20.4 ± 3.4% vs. 54.1 ± 11.6%, total protein 2.4 ± 0.4 vs. 8.2 ± 2.9 gms/DL, fibrinogen 92.0 ± 20.3 vs. 305.8 ± 137.2 mg/DL. Parameters that were not significantly different but trended toward an increase post-Hemobag were platelet counts, heparin levels, white cell count, and plasma free hemoglobin. Parameters that showed no differences or trends included sodium, potassium, chloride, bicarbonate, and osmolarity. Processing times were measured at approximately 10 minutes. This device effectively concentrates post-bypass circuit volume, providing a product that is high in red blood cells and plasma proteins and may provide an alternative to current techniques for circuit volume salvage.
Key words: blood conservation / ultrafiltration / blood salvage / hemodilution / hemoconcentrator / Hemobag
© 2004 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.