Issue |
J Extra Corpor Technol
Volume 52, Number 4, December 2020
|
|
---|---|---|
Page(s) | 289 - 294 | |
DOI | https://doi.org/10.1051/ject/202052289 | |
Published online | 15 December 2020 |
Original Article
Cardiopulmonary Bypass Mean Global Oxygen Delivery May Be Associated with Neurocognitive Preservation during Hypothermic Aortic Surgery
Address correspondence to: Larry Garrison, PhD, MBA, CCP, Chief of CV Perfusion, Franciscan Health Indianapolis, 8111 South Emerson Ave., Indianapolis, IN 46237. E-mail: perfusionphd@gmail.com
Received:
2
July
2020
Accepted:
6
October
2020
The purpose of this retrospective research was to investigate the relationship between mean global oxygen delivery (DO2) and neurocognitive function in adult patients who presented for aortic surgery with deep hypothermic circulatory arrest using cardiopulmonary bypass (CPB). From a pool of 132 patients, data from 100 CPB patients from 2012 to 2014 aged 50 years or older were randomly selected and analyzed, and global DO2 on CPB was used to categorize patients into those for whom the mean indexed cerebral oxygen delivery (DO2i) was either ≥272 mL O2/min/m2 (critical DO2 [DO2crit]) or less than DO2crit. Ten patients experienced either stroke or expired in the perioperative course. The proportion of patients with evidence of neurocognitive preservation was 98.3% in the group in which the DO2crit was met, compared with 80.6% in the group where DO2crit was not met (X2 [1, 100] = 3.27, p = .07). Potentially, because of causes other than DO2, the subset of patients with stroke and/or death were removed, and data from 90 cases were analyzed, and a global mean DO2i value of 239.9 mL O2/min/m2 was identified. A larger sample size with controls may yield deeper insights into the hypothesis that a mean global CPB DO2i of 239.9 mL O2/min/m2 may play a role in predicting neurocognitive preservation in this patient population.
Key words: acute kidney injury (AKI) / cardiopulmonary bypass (CPB) / cerebral performance category (CPC) / neurocognitive preservation/loss / critical oxygen delivery (DO2crit) / modified Rankin Scale (mRS)
© 2020 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.