Open Access

Figure 2

image

Download original image

Adjusted receiver operating characteristic analysis of area under the curve (AUC) for DO2i340 and any stage CS-AKI for neonates in STAT categories 4 and 5, n = 463 patients. A logistic regression model after adjusting for CPB time (> 90 min, ≤ 90 min), DHCA use (yes/no), nadir NP temperature, intraoperative transfusion (yes/no), patient race (White, Black, other), ethnicity (Hispanic, non-Hispanic), and preterm gestational age (yes/no), DO2i340 had the highest AUC of CS-AKI, 0.66 (95% CI = 0.60 – 0.72, sensitivity = 56.1%, specificity = 69.4%).

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.