Open Access

Table 4

Extracorporeal blood purification procedures.

Quantity of procedures
Type of procedure HA330 group n = 20 CytoSorb-300 group (n = 20) Control group (n = 20)
CVVHF, mean (range) 1 0 4
CVVHDF, mean (range) 5 4 5
CVVHD, mean (range) 1 0 6
OL-HDF, mean (range) 17 16 23
OL-HF, mean (range) 1 8 6
Intermittent HD, mean (range) 0 0 16
SLED, mean (range) 1 0 1
HP (HA 280), mean (range) 2 0 0
HP (HA330II), mean (range) 0 2 6
Total number of procedures 28 30 67

CVVHF – Continuous Veno-Venous Hemofiltration; CVVHDF – Continuous venovenous hemodiafiltration; CVVHD – Continuous venovenous hemodialysis; OL-HDF – Online haemodiafiltration; OL-HF – Online hemofiltration; Intermittent HD – Intermittent hemodialysis; SLED – sustained low-efficiency dialysis; HP (HA 280) – hemoperfusion cartridge HA 280; HP (HA330II) – hemoperfusion cartridge HA 330 II.