Issue |
J Extra Corpor Technol
Volume 37, Number 4, December 2005
|
|
---|---|---|
Page(s) | 387 - 389 | |
DOI | https://doi.org/10.1051/ject/200537387 | |
Published online | 15 December 2005 |
Original Articles
Second Generation of Minimal Invasive Extracorporeal Circuit: Pilot Study Resting Heart System
* Service de Chirurgie Cardiovasculaire, Hòpital Cardiologique, CHRU, Lille, France
† Service de Réanimation Cardiologique, Hòpital Cardiologique, CHRU, Lille, France
‡ Department of Cardiothoracic Surgery, NHLI, Imperial College Faculty of Medicine, London, United Kingdom
Address correspondence to: Georges Fayad, MD, Hôpital Cardiologique, 59037 Lille Cedex, France. E-mail: g-fayad@chru-lille.fr
Cardiopulmonary bypass (CPB) has evolved from a complex multifunctional system to the minimally invasive extra-corporeal circuit (MIEC). Concerns currently exist regarding the technically demanding nature of off-pump coronary artery bypass (OPCAB) procedures, the quality of anastomosis associated with it, and the difficulty in achieving “complete revascularization.” Recognizing these issues, the so-called mini-CPB concept has evolved in an effort to offer the perceived benefits of OPCAB with the technical advantages of CPB and at the same time minimize the adverse effects of full-scale CPB. The first generation of MIEC had an inherited risk of gas embolisms. Therefore, there was the introduction of the resting heart system (RHS), the main characteristic of which is the venous air removal device. The aim of this study was to describe our early experience, feasibility, and safety with this system to help others who are considering introducing this technique into their clinical practice. Using this system, we operated on 30 consecutive patients. Moderate hypothermia (33°C) CPB and cold intermittent antegrade cardioplegia was used. No technical incidents were encountered. One death from multiorgan failure occurred in a patient operated on for a thoraco-abdominal aneurysm. Our own short-term experience with the RHS has been very favorable, and we will continue to explore this development in CPB technology.
Key words: minimally invasive extracorporeal circuit
© 2005 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.