Issue |
J Extra Corpor Technol
Volume 37, Number 4, December 2005
|
|
---|---|---|
Page(s) | 390 - 395 | |
DOI | https://doi.org/10.1051/ject/200537390 | |
Published online | 15 December 2005 |
Scientific Article
Stability of Human Thrombin Produced From 11 ml of Plasma Using the Thrombin Processing Device
Address correspondence to: Vijay Kumar, PhD, Thermogenesis Corp., 2711 Citrus Road, Rancho Cordova, CA 95742. E-mail: vkumar@thermogenesis.com
Autologous thrombin can be produced by activating the patient’s own plasma. By adding calcium chloride (CaCl2) to the anticoagulated plasma, the coagulation cascade will be initiated, and active thrombin will be produced. However, thrombin obtained by this method degrades very quickly and is not practical for use during surgery. The aim of this study was to investigate the stability of the thrombin produced using the thrombin processing device (TPD; Thermogenesis Corporation). The TPD consists of a tubular chamber containing a negatively charged surface for activation. Plasma (11 ml) and reagent (CaCl2 and ethanol, 3.75 ml) were added to the TPD, and active thrombin was harvested after a 20-minute incubation. The production of thrombin was done at 18°C (64°F), 24°C (75°F), and 27°C (81°F) (n = 4/group). The produced thrombin was stored at the production temperature, 4°C (39°F), and 35°C (95°F). The thrombin activity was assessed by time to clot formation, using a fibrinogen concentrate as substrate, after 2, 4, and 6 hours of storage. Thrombin produced at 18°C had clot times of less than 5 seconds for 2 hours (4.42 ± 1.3 seconds) when stored at 4°C, but 4 hours (4.1 ± 1.3 seconds) when stored at 35°C. In contrast, when thrombin was produced at 24°C, the clot times were 4.3 ± 0.7 and 4.6 ± 1.6 seconds at 4°C and 35°C, respectively, for up to 6 hours. Similar results were obtained for thrombin produced at 27°C. Active thrombin produced by the TPD is dependent on both the production temperature and the storage temperature. Autologous human thrombin with a stability of up to 6 hours can be obtained using the TPD when produced at 24°C or 27°C and stored at 4°C.
Key words: human thrombin / stability / fibrinogen / clot / plasma
© 2005 AMSECT
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.